50A PCB Mount Closed Loop Current Transducer ± 15V Supply 4V Output
| Electrical characteristics | ||||||||||||
| Type | CSM005 SY  | CSM010 SY  | CSM015 SY  | CSM020 SY  | CSM025 SY  | CSM030 SY  | CSM050 SY  | |||||
| IPN | Primary nominal input current | 5 | 10 | 15 | 20 | 25 | 30 | 50 | A | |||
| IP | Measuring range of primary current | 0~±10 | 0~±20 | 0~±30 | 0~±40 | 0~±50 | 0~±60 | 0~±100 | A | |||
| Dimension of input terminal | Ф0.8 | Ф1.0 | Ф1.0 | Ф1.4 | Ф1.4 | Ф1.6 | 2×1.6×1.5 | mm | ||||
| KN | Conversion ratio | 3:1500 | 2:2000 | 1:1500 | 1:2000 | 1:2500 | 1:3000 | 1:3125 | ||||
| RIM | Internal measuring resistance | 400 | 400 | 400 | 400 | 400 | 400 | 250 | Ω | |||
| VOUT | Secondary nominal output voltage | 4±0.5% | V | |||||||||
| VC | Supply voltage | ±15(±5%) | V | |||||||||
| IC | Current consumption | <25 | mA | |||||||||
| VD | Insulation voltage | AC/50Hz/1min 2.5 | kV | |||||||||
| εL | Linearity | <0.1 | %FS | |||||||||
| VO | Zero offset voltage | TA=25℃ <±25 | mV | |||||||||
| VOT | Thermal drift of V0 | IP=0 TA=-25~+85℃ <±0.5 | mV/℃ | |||||||||
| TR | Response time | <1 | μs | |||||||||
| f | Frequency bandwidth(-3dB) | DC~200 | kHz | |||||||||
| TA | Ambient operating temperature | -25~+85 | ℃ | |||||||||
| TS | Ambient storage temperature | -40~+100 | ℃ | |||||||||
| Standard | Q/3201CHGL02-2007 | |||||||||||
| Dimensions of drawing (mm) | 
  | 
| Remarks | 
·Incorrect connection may lead to the damage of the sensor. ·VOUT is positive when the IP flows in the direction of the arrow.  | 
                                 
                             |